R-KEM II with Threaded Rods for Masonry
Universal polyester (styrene free) resin - European Approval for 15 substrates
Features and benefits
- Available in a winter version with faster curing time. It can be used from -20°C.
- Three colors - standard, stone & gray
- The most convenient bonded anchor for general purpose use
- Approved for 15 substrates
- Quick, secure and simple installation
- Product with wide spectrum of use in the medium load capacity area
- Ideal for applications where mechanical anchors are not suitable
- Easy dosage thanks to patented self-opening system and use of manual or electric gun
- Option of use standard manual silicone gun
- Suitable for multiple use. Partly used product can be reused after fitting new nozzle
Product information
Product Code |
Resin |
Description / Resin Type |
Volume |
[ml] | |||
R-KEM-II-175 |
R-KEMII |
Styrene Free Polyester Resin |
175 |
R-KEM-II-300 |
R-KEMII |
Styrene Free Polyester Resin |
300 |
R-KEM-II-410 |
R-KEMII |
Styrene Free Polyester Resin |
410 |
R-KEM-II-300-W |
R-KEMII-W |
Low Temperature (Winter) / Rapid Cure Styrene Free Polyester Resin |
300 |
R-KEM-II-300-S |
R-KEMII-S |
High Temperature (Summer) / Slow Cure Styrene Free Polyester Resin |
300 |
R-KEM-II-175-SET |
R-KEMII |
Set with 4 studs and plastic sleeves |
175 |
R-KEM-II-300-SET |
R-KEMII |
Set with 4 studs and plastic sleeves |
300 |
R-KEM-II-300-STONE |
R-KEMII |
Stone colour Styrene Free Polyester Resin |
300 |
R-KEM-II-410-STONE |
R-KEMII |
Stone colour Styrene Free Polyester Resin |
410 |
R-KEM-II-300-GREY |
R-KEMII |
Grey colour Styrene Free Polyester Resin |
300 |
R-KEM-II-410-GREY |
R-KEMII |
Grey colour Styrene Free Polyester Resin |
410 |
R-KEM-II-300-SV |
R-KEMII |
Styrene Free Polyester Resin |
300 |
Base material
-
Hollow Brick
-
Solid Brick
-
Hollow Sand-lime Brick
-
Solid Sand-lime Brick
-
Hollow Lightweight Concrete Block
-
Aerated Concrete Block
For use also with
-
Hollow-core Slab
Applications
- Gates
- Window elements
- Canopies
- Sanitary appliances
- Railings
- Handrails
- Consoles
- Ladders
- Cable trays
Installation guide
- Drill hole to the required diameter and depth for stud size being used.
- Solid substrates: Clean the drill hole thoroughly with brush and hand pump at least four times before installation.
- Hollow substrates: insert mesh sleeve into the hole.
- Insert cartridge into gun and attach nozzle.
- Dispense to waste until even colour is obtained.
- Solid substrates: Insert the mixer nozzle to the bottom of the drill hole and inject resin, slowly withdrawing the nozzle as the hole is filled to 70% of its depth.
- Hollow substrates: Insert the mixer nozzle to the bottom of the drill hole and inject resin, slowly withdrawing the nozzle as the hole is filled to 100% of its depth.
- Immediately insert the stud, slowly and with slight twisting motion. Remove any excess resin around the hole before it sets and leave it undisturbed until the curing time elapses.
- Attach fixture and tighten the nut to the required torque.
Installation data
AERATED CONCRETE
Size |
M8 |
M10 |
M12 |
M16 |
||
Thread diameter |
d |
[mm] |
8 |
10 |
12 |
16 |
Hole diameter in substrate |
d0 |
[mm] |
10 |
12 |
14 |
18 |
Installation torque |
Tinst |
[Nm] |
3 |
4 |
6 |
10 |
Min. hole depth in substrate |
h0 |
[mm] |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
Min. installation depth |
hnom |
[mm] |
80 |
85 |
95 |
105 |
Min. spacing |
smin |
[mm] |
50 |
50 |
50 |
54 |
Min. edge distance |
cmin |
[mm] |
50 |
50 |
50 |
54 |
CERAMIC SOLID SUBSTRATES
Size |
M8 |
M10 |
M12 |
M16 |
||
Thread diameter |
d |
[mm] |
8 |
10 |
12 |
16 |
Hole diameter in substrate |
d0 |
[mm] |
10 |
12 |
14 |
18 |
Installation torque |
Tinst |
[Nm] |
5 |
8 |
10 |
15 |
Min. hole depth in substrate |
h0 |
[mm] |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
Min. installation depth |
hnom |
[mm] |
80 |
85 |
95 |
105 |
Min. spacing |
smin |
[mm] |
50 |
50 |
50 |
54 |
Min. edge distance |
cmin |
[mm] |
50 |
50 |
50 |
54 |
HOLLOW SUBSTRATES
Size |
M8 |
M10 |
M12 |
M16 |
|||||
Thread diameter |
d |
[mm] |
8 |
8 |
10 |
10 |
12 |
12 |
16 |
Hole diameter in substrate |
d0 |
[mm] |
12 |
12 |
16 |
16 |
16 |
16 |
20 |
Installation torque |
Tinst |
[Nm] |
3 |
3 |
4 |
4 |
6 |
6 |
10 |
Min. hole depth in substrate |
h0 |
[mm] |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
Min. installation depth |
hnom |
[mm] |
50 |
80 |
85 |
125 |
85 |
125 |
85 |
Min. spacing |
smin |
[mm] |
100 |
100 |
100 |
100 |
100 |
100 |
120 |
Min. edge distance |
cmin |
[mm] |
100 |
100 |
100 |
100 |
100 |
100 |
120 |
Plastic mesh sleeve size |
[mm] |
12x50 |
12x80 |
16x85 |
16x130 |
16x85 |
16x130 |
20x85 |
Minimum working and curing time
R-KEM II
Resin temperature |
Concrete temperature |
Curing time* |
Working time |
[°C] |
[°C] |
[min] |
[min] |
5 |
-20 |
- |
- |
5 |
-15 |
- |
- |
5 |
-10 |
- |
- |
5 |
-5 |
8 h |
70 |
5 |
0 |
4 h |
45 |
5 |
5 |
2 h |
25 |
10 |
10 |
1.5 h |
15 |
15 |
15 |
1 h |
9 |
20 |
20 |
45 |
5 |
25 |
30 |
30 |
2 |
25 |
35 |
- |
- |
25 |
40 |
- |
- |
*For wet concrete the curing time must be doubled
R-KEMII-W
Resin temperature |
Concrete temperature |
Curing time* |
Working time |
[°C] |
[°C] |
[min] |
[min] |
5 |
-20 |
24 h |
45 |
5 |
-15 |
18 h |
30 |
5 |
-10 |
8 h |
20 |
5 |
-5 |
5 h |
11 |
5 |
0 |
2 h |
7 |
5 |
5 |
1 h |
5 |
10 |
10 |
45 |
2 |
15 |
15 |
30 |
1.5 |
20 |
20 |
15 |
1 |
25 |
30 |
- |
- |
25 |
35 |
- |
- |
25 |
40 |
- |
- |
*For wet concrete the curing time must be doubled
R-KEMII-S
Resin temperature |
Concrete temperature |
Curing time* |
Working time |
[°C] |
[°C] |
[min] |
[min] |
5 |
-20 |
- |
- |
5 |
-15 |
- |
- |
5 |
-10 |
- |
- |
5 |
-5 |
24 h |
180 |
5 |
0 |
18 h |
120 |
5 |
5 |
12 h |
60 |
10 |
10 |
8 h |
45 |
15 |
15 |
6 h |
25 |
20 |
20 |
4 h |
15 |
25 |
30 |
1.5 h |
7 |
25 |
35 |
1 h |
6 |
25 |
40 |
45 |
5 |
*For wet concrete the curing time must be doubled
Downloads
- R-KEM II with Threaded Rods for Masonry - Technical Data Sheet
- scan.pdf
- ETAS-12_0528 EN.pdf
- UKTA-0836-22-6108_2022_R-KEMII_EN.pdf
Need documents for other product? Visit our Technical Library.