R-RBL-PF Rawlbolt® - Loose bolt with plastic ferrule
World's most popular all-purpose expanding shield anchor - loose bolt with plastic ferrule version
Features and benefits
- For use in concrete, hollowcore slabs, flooring blocks and ceramics
- Plastic ferrule simplifies installation in hollow substrates
- Wide range of diameters (M6 to M16)
- Three-pieces expanding sleeve of maximum expansion provides optimal load and safety of use in any substrate
Product information
Size |
Product Code |
Approval type |
Anchor |
Fixture |
|||
Diameter |
External diameter |
Length |
Max. thickness |
Hole diameter |
|||
d |
dnom |
L |
tfix |
df |
|||
- |
[mm] |
[mm] |
[mm] |
[mm] |
[mm] |
||
M6 |
R-RBL-PF-M06/10W |
AT-15-7280/14 |
6 |
12 |
55 |
10 |
6.5 |
R-RBL-PF-M06/25W |
AT-15-7280/14 |
6 |
12 |
70 |
25 |
6.5 |
|
R-RBL-PF-M06/40W |
AT-15-7280/14 |
6 |
12 |
85 |
40 |
6.5 |
|
M8 |
R-RBL-PF-M08/10W |
AT-15-7280/14 |
8 |
14 |
65 |
10 |
9 |
R-RBL-PF-M08/25W |
AT-15-7280/14 |
8 |
14 |
80 |
25 |
9 |
|
R-RBL-PF-M08/40W |
AT-15-7280/14 |
8 |
14 |
95 |
40 |
9 |
|
M10 |
R-RBL-PF-M10/10W |
AT-15-7280/14 |
10 |
16 |
75 |
10 |
11 |
R-RBL-PF-M10/25W |
AT-15-7280/14 |
10 |
16 |
90 |
25 |
11 |
|
R-RBL-PF-M10/50W |
AT-15-7280/14 |
10 |
16 |
115 |
50 |
11 |
|
R-RBL-PF-M10/75W |
AT-15-7280/14 |
10 |
16 |
140 |
75 |
11 |
|
M12 |
R-RBL-PF-M12/10W |
AT-15-7280/14 |
12 |
20 |
90 |
10 |
13 |
R-RBL-PF-M12/25W |
AT-15-7280/14 |
12 |
20 |
105 |
25 |
13 |
|
R-RBL-PF-M12/40W |
AT-15-7280/14 |
12 |
20 |
120 |
40 |
13 |
|
R-RBL-PF-M12/60W |
AT-15-7280/14 |
12 |
20 |
140 |
60 |
13 |
|
M16 |
R-RBL-PF-M16/15W |
AT-15-7280/14 |
16 |
25 |
135 |
15 |
17 |
R-RBL-PF-M16/30W |
AT-15-7280/14 |
16 |
25 |
150 |
30 |
17 |
|
R-RBL-PF-M16/60W |
AT-15-7280/14 |
16 |
25 |
180 |
60 |
17 |
Base material
-
Solid clay brick ≥ 20MPa
-
Hollow Lightweight Concrete Block LAC 5 ≥ 5MPa
-
Hollow Sand-lime Brick ≥ 15MPa
-
Concrete hollow floor block (eg. Teriva)
-
Hollow-core Slab C20/25
-
Hollow-core Slab C30/37-C50/60
For use also with
-
Cracked concrete C20/25-C50/60
-
Non-cracked concrete C20/25-C50/60
-
Unreinforced concrete
-
Reinforced concrete
-
Natural Stone (after site testing)
Applications
- Roller shutter doors
- Fire doors
- Steelwork
- Security grills
- Heavy machinery
- Pipework/ductwork supports
Installation guide
- Drill a hole of required diameter and depth
- Remove pre-assembled bolt and washer. Insert shield into hole and tap home with hammer until flush with surface
- Insert bolt with washer through fixture into the shield
- Tighten to the recommended torque
Installation data
Size |
M6 |
M8 |
M10 |
M12 |
M16 |
||
Thread diameter |
d |
[mm] |
6 |
8 |
10 |
12 |
16 |
Hole diameter in substrate |
d0 |
[mm] |
12 |
14 |
16 |
20 |
25 |
Min. installation depth |
hnom |
[mm] |
45 |
50 |
60 |
80 |
120 |
Min. hole depth in substrate |
h0 |
[mm] |
50 |
55 |
65 |
85 |
125 |
Wrench size |
Sw |
[mm] |
10 |
13 |
17 |
19 |
24 |
SOLID SUBSTRATES | |||||||
Installation torque |
Tinst |
[Nm] |
6.5 |
15 |
27 |
50 |
120 |
Min. substrate thickness |
hmin |
[mm] |
100 |
100 |
100 |
100 |
142 |
Min. spacing |
smin |
[mm] |
35 |
40 |
50 |
60 |
95 |
Min. edge distance |
cmin |
[mm] |
53 |
60 |
75 |
90 |
143 |
CERAMIC AND HOLLOW SUBSTRATES | |||||||
Installation torque |
Tinst |
[Nm] |
3 |
5 |
8 |
10 |
15 |
Min. spacing |
smin |
[mm] |
100 |
100 |
100 |
100 |
100 |
Min. edge distance |
cmin |
[mm] |
100 |
100 |
100 |
100 |
143 |